Table of Contents | ||||
---|---|---|---|---|
|
ShipHawk-Acumatica Connector 5.0
March 29, 2024
Users can map to/from the notes section in ShipHawk to Acumatica.
Feature to map some parameters from Acumatica as ultimate_consignee_address.
Fixed Shipment date issue.
Shipment notes disable option.
Added SKU description field for ShipHawk Order Mapping page.
Fixed Order Total Price mapping issue.
Fixed ShipHawk shipment confirmation issue.
Fixed contents of selected packages duplicates issue
Fixed issue with ShipHawk package stopping other customization action items.
ShipHawk-Acumatica Connector 4.3
October 20, 2023
The ShipHawk-Acumatica Connector 4.3 is an application that connects ShipHawk to the Acumatica ERP system. The application is an Acumatica Certified Application (ACA): it adheres to standards set for Acumatica integration and functionality.
Please contact your ShipHawk account manager or solutions engineer to get a copy of the ShipHawk-Acumatica Connector 4.3 package.
This release includes new features and minor issue fixes. (ShipHawk-Acumatica Connector 4.3 Release Notes also available on HubSpot.)
Requirements
Acumatica Versions Supported
ShipHawk-Acumatica Connector 4.3 only supports the following versions of Acumatica:
2022 R2
2023 R1
Acumatica License Requirements
Acumatica Modules
The ShipHawk solution requires following modules to be enabled:
Distribution module
Minimal License Tier
In alignment with Acumatica ERP license tier restrictions, the minimal recommended Acumatica ERP license tier needed for the ShipHawk-Acumatica Connector is:
S License Tiers
Installation
Important: ShipHawk recommends that you work with your Acumatica VAR to update packages because there may be dependencies.
For information on installing the ShipHawk-Acumatica Connector, see the ShipHawk-Acumatica Connector Installation Guide.
New Features
The following provides an overview of the new features in the ShipHawk-Acumatica Connector 4.3 release.
Tracking Update in ShipHawk Updates Acumatica Shipment
In some cases, the PRO number is returned by the LTL carrier after the shipment is booked. For these cases, ShipHawk now provides functionality to allow the PRO number to be updated in Acumatica.
(Internal ID: SHHS-82)
Sending Packed Orders from Acumatica to ShipHawk
The ShipHawk-Acumatica Connector now provides the ability to send Packed Orders from Acumatica to ShipHawk. When this feature is enabled, packed orders are sync’d from Acumatica to ShipHawk through the shipment's Packages tab.
(Internal ID: SHHS-97)
Increased Number of Reference Mappings
Some merchants need to be able to create more reference number mappings than were currently supported. The connector now supports 10 additional reference mappings, increasing the maximum number of mappings from 25 to 35.
(Internal ID: SHHS-105)
Change Packages Tab Generation for LTL Orders to Show Only Pallet
Some merchants require that for LTL shipments, ShipHawk only populates pallets in the Packages tab, which helps with sending the right information to SPS Commerce. This functionality can be enabled as needed.
(Internal ID: SHHS-106)
SCAC Code and BOL Number Writeback
ShipHawk now writes back the SCAC code and BOL number for the carrier to Acumatica, so that they can be communicated to EDI customers.
(Internal ID: SHHS-124)
Update Shipment Date Field While Importing Shipment Information
ShipHawk now updates the native shipment date field after the shipment has been confirmed.
(Internal ID: SHHS-125)
Combined Order FIxes for ShipHawk API Changes
Recently, ShipHawk TMS made some changes to how ShipHawk shows the order number for combined orders. Corresponding changes have been made to the ShipHawk-Acumatica connector as required for combined orders.
(Internal ID: SHHS-128)
ShipHawk-Acumatica Connector 4.2
March 23, 2023
ShipHawk-Acumatica Connector 4.2 Release Notes also available on HubSpot.
Requirements
Acumatica Versions Supported
ShipHawk-Acumatica Connector 4.2 only supports the following versions of Acumatica:
2022 R1
2022 R2
Acumatica License Requirements
Acumatica Modules
The ShipHawk solution requires following modules to be enabled:
Distribution module
Minimal License Tier
In alignment with Acumatica ERP license tier restrictions, the minimal recommended Acumatica ERP license tier needed for the ShipHawk-Acumatica Connector is:
S License Tiers
Installation
Important: ShipHawk recommends that you work with your Acumatica VAR to update packages because there may be dependencies.
For information on installing the ShipHawk-Acumatica Connector, see the ShipHawk-Acumatica Connector Installation Guide.
New Features
The following provides an overview of the new features in the ShipHawk-Acumatica Connector 4.2 release.
...